PRODUCT
The System Sensor BEAM1224 is transmitter / receiver unit and a reflector as fourwire conventional projected beam smoke detectors.
The InnovairFlex™ Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between.
The System Sensor BEAM1224S is transmitter / receiver unit and a reflector as fourwire conventional projected beam smoke detectors.
The SD-651 is designed to meet the performance criteria designated by UL. Its sensing chambers are sealed against back pressure air flow, dirt, and insects.
System Sensor’s 800 series detectors are 2-wire conventional profile plug-in detectors aimed to meet the performance criteria designated by UL.
System Sensor’s 5600 Series mechanical heat detectors offer a low-cost option for property protection against fire and for non-life-safety installations, where smoke detectors are inappropriate.
The 5151 thermal detector meets the needs for applications where rapid response is vital and rapid temperature increases would only be caused by a fire emergency.
The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise.
Notifier 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors.
Notifier FST-851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors.
The FSM500K provides both signaling of an alarm to the Fire Indicator Panel and local LED indication of activation.
Notifier 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors.
FCM-1 Addressable Control Module provides Notifier intelligent control panels a circuit for Notification Appliances (horns, strobes, speakers) or to monitor a telephone circuit.
FRM-1 Addressable Relay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, dampers, control equipment, etc.
FMM-1 is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices.
FMM-101 is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices.
The NOTIFIER ISO-X Fault Isolator Module is used with the NFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100 and System 5000 (equipped with an AIM-200 module) to protect the system against wire-to-wire short circuits on the SLC loops.
The FRM-1 Relay Control Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built-in rotary switches.
FDM-1 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems.
The SpectrAlert Advance SPCWK-R (replacement model) is a white, outdoor, ceiling-mount speaker. Offers mounting plate only – no back box included.